Look carefully at the pressure gauge, if it jumps about when heating is on and goes from 1 to 3 or so quickly, then it is the expansion vessel. Otherwise I agree with the other post that it is the PRV. goood luck.
Colin, Chris, Chunky, Kev, Ozzie, Ron, Whizzer, me Muller,Pete, Terry, Brian ( Use me ) Dildo, many more but this was the core of the team, are you any of these or can you name those I have forgotten.
Absolutly correct, any external condense pipework should be in 32mm but if not it should be lagged, it must also run downhill all the way with no horizontal runs or drooping pipework.it is very easy to replace as there is no pressure or need to drain the boiler etc but of course I can't...